A Modified Model for Automatic Generation Control in Deregulated Power Systems
Full Text(PDF, )  PP.914-919  
Author(s)
K. Hari Krishna, Dr. K. Chandra Sekhar
KEYWORDS
Automatic Generation Control, Bilateral Contracts, Power Systen Control, Deregulation.
ABSTRACT
AGC in deregulated power system is modeled by modifying conventional model with inclusion of bilateral contracts. Bilateral contracts will allow DISCOs in one area to get power from another area. This inclusion complicates the design of the controller by
References
[1] J. Kumar, K. Ng, and G. Sheble, “AGC simulator for price-based operation: Part I,” IEEE Trans. Power Systems, vol. 12, no. 2, May 1997.

[2] “AGC simulator for price-based operation: Part II,” IEEE Trans. Power Systems, vol. 12, no. 2, May 1997.

[3] O. I. Elgerd and C. Fosha, “Optimum megawatt-frequency control of multiarea electric energy systems,” IEEE Trans. Power Apparatus & Systems, vol. PAS-89, no. 4, pp. 556–563, Apr. 1970.

[4] C. Fosha and O. I. Elgerd, “The megawatt-frequency control problem: A newapproach via optimal control theory,” IEEE Trans. Power Apparatus & Systems, vol. PAS-89, no. 4, pp. 563–577, Apr. 1970.

[5] R. Christie and A. Bose, “Load-frequency control issues in power systems operations after deregulation,” IEEE Trans. Power Systems, vol. 11, pp. 1191–1200, Aug. 1996.

[6] E. Nobile, A. Bose, and K. Tomsovic, “Bilateral market for load following ancillary services,” in Proc. PES Summer Power Meeting, Seattle, WA, July 15–21, 2000.

[7] M. Ilic, F. Galiana, and L. Fink, Eds., Power Systems Restructuring: Engineering & Economics. Boston: Kluwer Academic Publishers, 1998.

[8] G. B. Sheble, Computational Auction Mechanisms for Restructured Power Industry Operation. Boston: Kluwer Academic Publishers, 1999.

[9] R. D. Christie, B. F. Wollenberg, and I. Wangensteen, Transmission management in the deregulated environment,” Proc. IEEE Special Issue on The Technology of Power System Competition, vol. 88, no. 2, pp. 170–195, Feb. 2000.

[10] J. L.Willems, “Sensitivity analysis of the optimum performance of conventional load-frequency control,” Trans. Power Apparatus & Systems, vol. 93, no. 6, pp. 1287–1291, Sept./Oct. 1974.

[11] P. V. Kokotovic and R. Rutman, “Sensitivity of automatic control systems (survey),” Automation and Remote Control, vol. 26, pp. 727– 749, 1965