Design and Fabrication of New Radon Chamber for Radon Calibration Factor of Measurement
Full Text(PDF, )  PP.214-219  
Author(s)
Murtadha S. Al-Nafiey,Mohamad S. Jaafar,Sabar Bin Bauk,N.F. Salih
KEYWORDS
Chamber Design; Calibration Factor; CR-39; Radon Monitor; Radon
ABSTRACT
This study consists of two parts: the first part is concerned with designing a new radon chamber that is constructed using a continuous radon monitor together CR-39 Nuclear Track Detectors (NTDs). The aim behind designing such a chamber is to measure rado
References
[1] United Nations Scientific Committee on the Effects of Atomic Radiations UNSCEAR Sources and effects of ionizing radiation. UN, New York, 1982.

[2] A.D.Wrixon, New ICRP recommendations .Journal of Radiological Protection, 28, 161-168, 2008.

[3] R. Shweikani, G. Raja, Design, construct and test of a calibration radon chamber, Radiat. Meas. 40, 316-319, 2005.

[4] D. Nikezic H., K.N. Yu, Computer program TRACK-TEST for calculation parameters and plotting profiles for etch pits in nuclear track materials, Comput. Phys. Commun. 174, 60, 2006.

[5] Y. S. Mayya, K. P. Eappen, K. S. V. Nambi, Methodology for mixed field inhalation dosimetry in monazite areas using a twin-cup dosimeter with three track detectors”, Rad. Prot. Dosim., 77(3), pp.177-184, 1998.

[6] Gil Hoon Ahn, Jai-Kilee , Construction of an environmental radon monitoring system using CR- 39 nuclear track detectors, Nucl.Eng. Technol.37 (4) 395-400, 2005.

[7] M. I. Al-Jarallah, Fazal-ur-Rehman, Khalid Abdalla , Comparative study of short and long-term indoor radon measurements , Radiat.Measure.43, S471-S474, 2008.

[8] A. H. Ismail, Mohamad S. Jaafar , Design and construct optimum dosimeter to detect airborne radon and thoron gas: Experimental study, Nucl. Instr. and Meth. In Phys. Res. B269, 437-439, 2011.

[9] Marcia Pires de Campos and Elaine Wirney Martins, Calibration of the solid state nuclear track detector CR-39 for radon measurements . INAC International Nuclear Atlantic Conference Santos, SP, Brazil, ASSOCIAÇÃO BRASILEIRA DE ENERGIA NUCLEAR – ABEN. ISBN: 978-85- 99141-02-1, 2007.

[10] J. C. H.Miles and E. J. Dew , A passive radon gas detector for use in homes. In Solid State Nuclear Track Detectors (Edited by Fowler P. H. and Clapham V. M.). Pergamon Press, Oxford , 1982.

[11] M. C Subba Ramu., T. S. Murlidharan and T. V. Ramachandran , Calibration of a solid state nuclear track detector for the measurement of indoor levels of radon and its daughters. Sci. Total Environ. 73, 245-255, 1988.

[12] J.Giridhar and M.Raghavayya , Calibration of cellulose nitrate film for measurement of time integrated concentration of Rn-222 in air. Report No. 1319, BARC, Bombay, 1986.