Design and Implementation of Maximum Power Point Tracking (MPPT) Algorithm for a Standalone PV System
Full Text(PDF, )  PP.428-434  
Author(s)
S.Gomathy, S.Saravanan, Dr. S. Thangave
KEYWORDS
:PV, MPPT, P&O, Incremental Conductance (INC),VSS INC
ABSTRACT
Maximum power point trackers (MPPTs) play a vital role in photovoltaic (PV) systems because they increase the efficiency of the solar photovoltaic system by increasing the power output. MPPT algorithms are necessary because PV arrays have a non linear voltage-current characteristic with a unique point where the power produced is maximum. The output power from the solar panel varies with solar irradiance, temperature and so on. To increase the power extracted from the solar panel, it is necessary to operate the photovoltaic (PV) system at the maximum power point (MPP). This paper presents the Matlab/simulink arrangement of perturb & observe (P&O) and incremental conductance (INC) MPPT algorithm which is responsible for driving the dc-dc boost converter to track maximum power point (MPP). This paper also presents the theoretical analysis of variable step size (VSS) of INC MPPT which can effectively improve the tracking speed and accuracy of maximum power
References
[1]. Trishan Esram, Jonathan W. Kimball, Philip T. Krein, Patrick L. Chapman, Pallab Midya,―Dynamic Maximum Power Point Tracking of Photovoltaic Arrays Using Ripple Correlation Control,‖ IEEE Trans.pwer Electron., vol 21, no5, pp. 1282-1291.(IEEE Transactions)

[2]. D. Sera, R. Teodorescu, J. Hantschel, and M. Knoll, ―Optimized maximum power point tracker for fast-changing environmental conditions,‖IEEE Trans. Ind. Electron., vol. 55, no. 7, pp. 2629–2637, Jul. 2008.(IEEE Transactions)

[3]. Vikrant.A.Chaudhar,‖Automatic peak power tracker for solar pv modules‖ July 2005

[4]. T. Esram and P. L. Chapman, ―Comparison of photovoltaic array maximum power point tracking techniques,” IEEE Trans. Energy Convers.,vol. 22, no. 2, pp. 439–449, Jun. 2007.(IEEE Transactions)

[5]. G. Petrone, G. Spagnuolo, R. Teodorescu, M. Veerachary, and M. Vitelli,―Reliability issues in photovoltaic power processing systems,‖ IEEE Trans. Ind. Electron., vol. 55, no. 7, pp. 2569–2580, Jul. 2008.(IEEE Transactions)

[6]. K. Noppadol, W. Theerayod, and S. Phaophak, ―FPGA implementation of MPPT using variable step-size P&O algorithm for PV applications,‖ in Proc.ISCIT, 2006, pp. 212–215.(Conference proceedings)

[7]. A. Pandey, N. Dasgupta, and A. K. Mukerjee, ―Design issues in implementing MPPT for improved tracking and dynamic performance,‖ in Proc. IEEE IECON, 2006, pp. 4387–4391.(Conference proceedings)

[8]. N.Mutoh,T.Matuo,K.Okada,andM.Sakai,―Prediction-databased maximum-power-point-tracking method for photovoltaic power generation systems,‖ in Proc. 33rd Annu. IEEE Power Electron. Spec. Conf.,2002, pp. 1489–1494.(Conference proceedings)

[9]. B. M.Wilamowski and X. Li, ―Fuzzy system based maximum power point tracking for PV system,‖ in Proc. 28th Annu. Conf. IEEE Ind. Electron.Soc., 2002, pp. 3280–3284.(Conference proceedings)

[10]. F. Liu, S. Duan, F. Liu, B. Liu, and Y. Kang, ―A variable step size INC MPPT method for PV systems,” IEEE Trans. Ind. Electron., vol. 55, no. 7,pp.2622–2628, Jul. 2008.(IEEE Transactions)

[11]. H. S. Bae, S. J. Lee, K. S. Choi, B. H. Cho, and S. S. Jang, ―Current control design for a grid connected photovoltaic/fuel cell DC–AC inverter,‖ in Proc. 24th IEEE APEC, Feb. 15–19, 2009, pp. 1945– 1950.(Conference proceedings)

[12]. X. Sun, W. Wu, X. Li, and Q. Zhao, ―A research on photovoltaic energy controlling system with maximum power point tracking,‖ in Proc. Power Convers. Conf., 2002, pp. 822–826.(Conference proceedings)

[13] Emad M. Ahmed and Masahito Shoyama ,‖Variable Step Size Maximum Power Point Tracker Using a Single Variable for Standalone Battery PV Systems, Journal of Power Electronics, Vol. 11, No. 2, March 2011 JPE.(Journal).