Online Graphical Display of Blood Oxygen Saturation and Pulse Rate
|
Full Text(PDF, 3000) PP.
|
|
Author(s) |
Dilpreet Kaur, Sukhwinder Kumar, Shashi Sharma |
|
KEYWORDS |
Heart rate, microcontroller, oxygen saturation, pulse oximeter
|
|
ABSTRACT |
This paper will design a non-invasive pulse oximeter using the ADuC842 microcontroller. A pulse oximeter is a medical device that indirectly monitors the oxygen saturation of a patient's blood and heart rate. The hardware has been developed for the pulse oximeter and programming/coding has been done for calculating blood oxygen saturation and pulse rate of a patient. The results are displayed on the OLED or transported to PC. The software used is ASPIRE (Advanced Systems Programming Integrating Real-time Emulation) verion 1.05. Assessing a patient's need for oxygen is the most essential element to life; no human life thrives in the absence of oxygen.
|
|
References |
|
[1] Cho Zin Myint, Nader Barsoum, Wong Kiing Ing, “Design a medicine
device for blood oxygen concentration and heart beat rate”,Global Journal on Technology and Optimization, June 2010.
[2] Maziar Tavakoli, Student Member, IEEE; Lorenzo Turicchia, and
Rahul Sarpeshkar, Senior Member, IEEE, “An Ultra-Low-Power
Pulse Oximeter Implemented with an Energy-Efficient Transimpedance
Amplifier”, IEEE transactions on Biomedical circuits and
systems, VOL. 4, NO. 1, February 2010.
[3] Pawan K. Baheti, Harinath Garudadri, “An Ultra low power pulse
oximeter sensor based on compressed sensing”, IEEE Computer
Society, 2009.
[4] Susannah Fleming, Lionel Tarassenko, Matthew Thompson, and
David Mant, “Non-invasive Measurement of Respiratory Rate in
Children Using the Photoplethysmogram”, 30th Annual International
IEEE EMBS Conference, August 2008.
[5] Stephan Reichelt_, Jens Fiala, Armin Werber, Katharina Förster,
Claudia Heilmann, Rolf Klemm, and Hans Zappe, “Development
of an Implantable Pulse Oximeter”, IEEE transactions on Biomedical
Engineering, VOL. 55, NO. 2, February 2008.
[6] Guowei Di, Xiaoying Tang, Weifeng Liu, “A Reflectance Pulse
Oximeter Design Using the MSP430OF149”, IEEE/ICME International
Conference on Complex Medical Engineering, 2007.
[7] Hassan Deni, Diane M. Muratore, Robert A. Malkin, “Development
of a Pulse Oximeter Analyzer for the Developing World”, IEEE,
2005.
[8] Panayiotis A. Kyriacou, Sarah Powell, Richard M. Langford, and
Deric P. Jones, “Esophageal Pulse Oximetry Utilizing Reflectance
Photoplethysmography”, IEEE transactions on Biomedical Engineering,
VOL. 49, NO. 11, November 2002.
[9] Juan M. Lopera, Juan Diaz, Miguel J. Pneto and Fernando Nuno,
“Pulse oximeter for homecare”, IEEE Proceedings of the Second
Joint EMBSBMES Conference, October 2002.
|
|
|