International Journal of Scientific & Engineering Research, Volume 5, Issue 6, June-2014 66

ISSN 2229-5518

Comparative Analysis of EDFA based 64 channel

WDM systems for different pumping techniques

Mishal Singla, Preeti, Sanjiv Kumar

Abstract – Wavelength Division Multiplexing using optical network is widely used in telecommunication system because it play an important role in next upcoming networks. So,the different pumping techniques for 64 channel W DM system for different length of Erbium doped fiber are discussed in this paper. For the same, system is analyzed on the basis of Bit Error Rate (BER), Received power and Q- Factor in the wavelength range of 1530nm to 1562nm at power-26dBm with 0.5nm spacing. The effect of different pumping techniques is also compared to find the suitable pumping technique and optimized BER at the receiver end.

Index Term – EDFA; Pump power; Fiber length; Bit error rate; W DM

1 INTRODUCTION

—————————— ——————————
fluorescence, Erbium ions are efficiently used for
amplification in optical domain [6]. When an optical signal at
1550 nm wavelength enters the EDFA, the signal is combined

F OR the past two decades, Optical Fiber Communication

has been advanced rapidly as it is the process of achieving transmission bandwidth using optical waves as carrier. As the time goes for the further improvement of Optical Fiber Communication, need of coherent optical sources arises and lasers are developed [1]. But when a signal travels in an optical fibrevarious losses like attenuation, tap splice etc. occurs. In presence of such losses, it is difficult to detect the received signal. Therefore, for the long transmission, these losses have to be overcome in fibre using different means. One such mean is the use of fibre amplifier. Also, far before, the optical signals were converted to electrical signal then amplified and then reconverted to optical signal. But it was a complex and costly process. As the optical amplifiers are introduced, the conversion of signal to electrical signal is not required. So, optical amplifiers revolutionized the optical fibre communication field [3]. Optical amplifiers broadly are of two types: semiconductor amplifier and fibre amplifier. Fibre amplifiers are divided into Erbium Doped Fibre Amplifier (EDFA), Raman amplifier and Brillouin amplifier [4].

————————————————

Mishal Singla is currently pursuing masters degree program in electronics and communication engineering in University Institute of Engineering and Technology, Panjab University, India. E-mail: singla.mishal@gmail.com

Preeti, Sanjiv Kumar are currently working as a assistant professor in electronics and communication department at University Institute of Engineering and Technology, Panjab University, India. E-mail: preeti_singh@pu.ac.in,sanjivsam86@gmail.com

For communication, there are practically two wavelength widows 1530nm to 1560nm(C-Band) and 1560nm to 1600nm (L-Band) [5]. EDFA can amplify a wide wavelength Range (1500nm - 1600nm) simultaneously , hence is very useful in wavelength division multiplexing for amplification. It is a
Conventional Silica fibre heavily doped with active
Erbium ions as the gain medium. Due to its property of
with a 980 nm or 1480nm pump laser through a wavelength division multiplexer device. The input signal and pump laser signal pass through fibre doped with Erbium ions .Erbium doped ions can be amplified the signal through the interaction at 1550nm [2]. EDFA is pumped in three ways: Co- Pumping, Counter pumping and Bidirectional Pumping. The performance of EDFA based WDM System depends on [7]:
1. Length of Erbium Doped Fibre
2. Pump Power
The performance analysis of a WDM (Wavelength Division
Multiplexing) system employed for long haul transmission is carried out in terms of Bit Error Rate (BER), Noise Figure and received Power [8]. In this paper, different techniques of pumping i.e. co-pumping, counter-pumping and bidirectional
pumping are analyzed for 64 channels in C- band [9] at 0.5 spacing for pump laser at 200mW at 980nm .

2 SYSTEM DESIGN AND ANALYSIS

2.1System Consideration:

There are three basic sections of a WDM system i.e. transmitter, channel and the receiver. The transmitter section includes: 64 channel WDM transmitter, ideal multiplexer; communication channel includesideal isolator, Erbium Doped Fiber, Optical Fiber ; whereas Photodiode, low pass filter are a part of the receiver section[6]. BER analyzer and optical power meter are used to analyze the simulation results.

2.2WDM System Design:

The system is designed in OptiSystem v7.0. In this, 64 channel
WDM signals are given at the input in the range of 1530nm-
1562nm having frequency spacing of 0.5nm at 10Gbps. The
input power of -26dBm is given to the channels. Doped ions
are excited to the higher energy level, when they pumped at
980nm.To prevent the effect of Amplified Spontaneous
Emission(ASE), isolator is used at the input end which also
prevent the propagation of the signal in backward direction.
Otherwise, population inversion is reduced due to

IJSER © 2014 http://www.ijser.org

International Journal of Scientific & Engineering Research, Volume 5, Issue 6, June-2014 67

ISSN 2229-5518

reflectedASE. Also,in EDFA, reflections of the output re-enter, and to overcomethis, isolatoris used at the output [7]. In this paper, three pumping techniques are compared i.e. Co- pumping, Counter pumping and Bidirectional pumping.

2.2.1 Co-Pumping (Forward Pumping):

In Co-Pumping, the signals i.e input and pump, travel in the same direction in the fiber. These signals are combined using a pump co-coupler or wavelength division multiplexer. Inside the fiber, pump energy is given to signal at the input and amplified signal is received at the amplifier’s output. In this design, for the propagation of the signal in one direction, isolators are used.

2.2.2 Counter-Pumping (Backward Pumping):

In Counter Pumping, both the signals i.e input and pump, travel in opposite direction to each other in the fiber. For amplification the direction of input and pump signal is not essential. They can travel in any direction.

2.2.3 Bidirectional-Pumping:

In Bi-directional, both the signals i.e input and pump, propagate in one direction. But in the fiber, two pump signals travel. One pump signal propagate in the same direction as the input signal and the other pump signal propagate in the direction opposite to that of signal at the input.

Figure1: Block Diagram of three pumping techniques (a) Co-Pumping (b) Counter- Pumping (c) Bidirectional Pumping

3 RESULTS AND DISCUSSION

Optimization of different parameters is needed to be done so that system performance does not degrade too low. The parameters which are to be considered are pump power, length of EDFA and length of optical fiber. Input Power is taken to be -26dBm. Length of EDFA is varied from 4m to 10m [4]. Length of optical fiber is taken to be 25km andoptimized power of the pump is200mW at
980nm wavelength. Length of the Erbium Doped Fiber is increased and corresponding received power is recorded for different pumping techniques as shown in table1, table2, table3, table4.

TABLE1

POWER WITH THE VARYING LENGTH OF EDFA FOR CO-PUMPING TECHNIQUE

IJSER © 2014 http://www.ijser.org

International Journal of Scientific & Engineering Research, Volume 5, Issue 6, June-2014 68

ISSN 2229-5518

EDFA length. For higher length of EDFA bidirectional pumping and co-pumping will give better results. Comparing the table 1, table 2 and table 3 it can be concluded that the bidirectional pumping gives the maximum output power with EDFA length of 10m.

TABLE2

POWER WITH THE VARYING LENGTH OF EDFA FOR COUNTER-

PUMPING TECHNIQUE

TABLE 4

BER ANALYSIS FOR DIFFERENT PUMPING TECHNIQUES FOR EDFA

LENGTH OF 4M TO 10M

TABLE3

POWER WITH THE VARYING LENGTH OF EDFA FOR BIDIRECTIONAL -

PUMPING TECHNIQUE

Length of EDFA ( m)

Input power(E-

6)

Input Power (In dBm)

Output

Power(E-3)

Output Power (In dBm)

4

87.891

-10.561

113.020

20.532

6

87.891

-10.561

112.943

20.529

8

87.891

-10.561

110.198

20.422

10

87.891

-10.561

107.335

20.307

In the bidirectional pumping, power of each pump laser is maintained to be 100mW i.e. 100mW through co-coupler and
100mW through counter- coupler but total power for pumping is
maintained to be 200mW for EDFA It can be observed from table
1, table 2 and table 3 that with the increase in length of EDFA the
received power increase. Also it can be seen from table 2 that for
counter pumping the transmission is acceptable up to 8m of
From table 4, it can be observed that variation in BER of counter pumping is more than the variation in co-pumping and bidirectional pumping. So for 64 channels counter pumping is not preferred. Further, simulation results show that BER for co- pumping lies in e-20 to e-22, for counter-pumping lies in e-17 to e-21 and for bidirectional pumping lies in e-20 to e-22.
Similarly, the performance can be visualized from eye diagrams given in figure 4.

(a)

IJSER © 2014 http://www.ijser.org

International Journal of Scientific & Engineering Research, Volume 5, Issue 6, June-2014 69

ISSN 2229-5518


(b)

(c)

Figure 4: Eye diagram for (a) Co-pumping (b) Counter pumping (c)

Bidirectional pumping

Figure 5: Q-factor Analysis for different pumping techniques

1.

Q-factor (Quality Factor) for different pumping techniques lies between 8.5 to 9.7 and BER between e-17 to e-22.
Further, from the above results, received power in case of co- pump is less for higher length of EDFA (6m-10m). After considering all the factors, bidirectional pumping for 64 channels is optimized to have the received power of about 20dBm.

4 CONCLUSION

Comparative analysis of three pumping techniquesis given in this paper i.e co-pumping, counter pumping and bidirectional in terms of BER(Bit error rate) and Q-factor for different length of EDFA( 4m to 10m) in C-Band at input power of -26dBm and pump power of 200mW at 980nm pump wavelength. In case of co-pumping, received power decreases with increase in length of EDFA and BER lies in e-20 to e-22. For counter pumping, received power increases with increase in length and BER lies in e-17 to e-21, but transmission is acceptable up to 8m EDFA length. For bidirectional pumping, power decreases but provides more power as compare to other configurations and BER between e-20 to e-21 for 100mW pump lasers. So, for longer length of EDFA (8m-10m), bidirectional pumping will provide better and optimized results.

REFERENCES

[1] HariBhagwan Sharma, Tarun Gulati, Bharat Rawat, “ Evaluation of Optical Amplifiers”, International Journal of EngineeringRresearch and Applications, ISSN: 2248-9622, Vol. 2, pp.663-667, 2012.

[2] Simaranjit Singh, Amanpreet Singh, R.S. Kaler, “Performance evaluation of

EDFA, Ramanand SOA optical amplifier for WDM systems”, Elsevier, Optik

124, 95-101, 2013.

[3] Simaranjit Singh, R.S. kaler, “Hybrid Optical amplifiers for 64X10 Gbps dense wavelength division multiplexed system”, Elsevier, Optik 124, 1311-1313,

2013.

[4] M. M.Ismail, M.A.Othman, Z.Zakaria, M.H.Misran, M.A.Meor Said, H.A.Sulaiman, M.N.ShahZainudin, M. A. Mutalib, “EDFA- WDM Optical Network design System”, Elsevier, Procedia Engineering 53,294-302, 2013.

[5] Prachi Shukla, KanwarPreet Kaur, “Performance Analysis of EDFA for different Pumping Configurations at High Data Rate”, IJEAT, ISSN: 2249 –

8958, Volume-2, Issue-5, June 2013.

[6] Dushyant Sharma, Dr. K.K.Saini, “ Performance Evaluation in order to achieve an stabilized output power obtained from EDFA without using an AGC”, International Conference on Advanced Computing & Communication Technologies, IEEE, 2013.

[7] P. Nagasivakumar, A. Sangeetha,”Gain Flatness of EDFA in WDM System”,

International conference on communication and signal processing,IEEE, 2013. [8] Farah Diana BintiMahadandAbu Sahmah Bin MohdSupa,” EDFA Gain

Optimization for WDM System”, Elektrika, Vol. 11, NO. 1, 34-37, 2009.

[9] Ramandeep Kaur, Rajneesh Randhawa, R.S. Kaler, “Performance evaluation of optical amplifier for 16x10,32x10 and 64x10 Gbps WDM system”, Elsevier Journal, Optik 124,693-700, 2013.

[10] Yugnanada Malhotra, R.S. Kaler, “Optimization of Super Dense WDM Systems for capacity enhancement”, Elsevier, Optik 123, 1497-1500, 2012.

[11] Jing Huang, “Impact of ASE noise in WDM systems”, Elsevier, Optik 122,

1376– 1380, 2011.